Straumann® TLC Implant System

Confidence in all indications.




The Straumann® TLC Implant System represents a new generation of tissue level implants. Designed with a slim apex and a focus on biological principles, the TLC implant reduces the risk of inflammation and bone resorption. Achieve unparalleled primary and secondary stability, even in compromised bone situations.



More treatment options

Versatile portfolio with additional diameters and lengths.

Simplicity and efficiency

Simple, but versatile portfolio featuring one prosthetic connection as well as shared instruments and prosthetics with Straumann® TLX.

Peri-implant health preservation

Reduced risk of bacterial nesting and optimized cleansability with the connection at the soft-tissue level.



SPARK YOUR EXCELLENCE

Straumann® TLC System highlights – innovative design to spark your excellence and perform in all indications. 

Precise cortical preparation

Perfectly matching profile drills for accurate preparation of the crestal bone.

Tapered design

Enables under-preparation of the bone and ensures high implant stability.

Extended cutting flutes

Self tapping properties remove the need for tapping.

Slim apex

For patient’s limited anatomy, such as converging root tips, facial undercuts or narrow atrophied ridges.

Machined collar neck

Manages the healing of peri-implant tissue and preserves soft tissue that forms around the implant during healing phase.



Torcfit™ connection

Internal conical connection engineered for high strength and slim abutment designs.

Strength of torx index
Six positions for flexible implant-abutment alignment

Precise fit of 7° conical connection
Precise implant-abutment fit

One size prosthetic connection across all implants
One single driver for all implants


Excellence through complete prosthetic portfolio

Consistent Emergence Profiles™ throughout the full portfolio, for easy soft-tissue conditioning across all indications.


FROM SINGLE UNIT TO FULL-ARCH

Excel with the Straumann® digital workflow.

The Straumann® digital workflow empowers your growth with a comprehensive range of straightforward and open solutions, streamlining and upgrading your workflow for the final benefit of your patients. You can confidently rely on a single provider for all your implant procedures.



Straumann® iEXCEL

Empowering you to excel

Straumann® iEXCEL is our ultimate Dental Performance System. Versatility of four implant designs in a single system. Simplicity of one prosthetic connection. Integrated digital workflows and services that help save your time.




Clinical Case

Guided surgery for immediate implant placement in the anterior zone after the fracture of a conventional bridge

Three apically tapered Straumann® TLC implants (∅ 4.5 mm x 12 mm) SLActive® Roxolid® were used. Ini- tially, a temporary denture was utilized. Subsequently, a provisional PMMA milled bridge was used for soft tissue modeling. Finally, a monolithic zirconia screw-retained bridge was fabricated on Variobase abutments

Shakeel Shahdad



  • Initial Situation

  • Pre Operative X-ray

  • Pre operative CBCT with implant plan

  • Fully guided flapless implant placement surgery after teeth extraction

  • Final implant position with healing abutment

  • Soft tissues at the time of delivery of definitive screw-retained prosthesis

  • Final restoration 6 m review

  • Follow up 6 m peri-apical radiograph



Clinical Case

Lower full arch surgery involved removal of old implants

Followed by immediate placement of 4 Straumann® TLC implants, ∅ 3.75 mm x 10 mm (44, 42, 32), ∅ 3.75mm x 12 mm (34) SLActive®, Roxolid® and immediate temporary restoration.

Louwrens Swart



  • Pre Operative X-ray, the diagnosis revealed that implants had to be explanted

  • 19Straumann® TLC MISSING CONTENT Pre Operative X-ray, the diagnosis revealed that implants had to be explanted Initial intraoral situation of the lower jaw showing 20 years old implants

  • Implants removal

  • Osteotomy preparation

  • Straumann® TLC Implant placement, 3.75 mm x 10 mm (44, 42, 32), 3.75 mm x 12 mm (34), SLActive®, Roxolid®

  • Healing abutment

  • Radiographic control

  • Loading within 48 hours, provisional restoration



Clinical Case

Lower molar tooth replacement in healed site

Utilizing digital planning for the replacement of a lower molar tooth in a healed site to establish a prosthetically-driven implant position. Conducting free-hand surgery for the placement of an apically tapered Straumann® TLC implant, ∅ 4.5mm x 10 mm SLActive®, Roxolid®. Following a healing period of 14 weeks, the digitally fabricated screw-retained crown is delivered.

Dr. Alessandro Perucchi & Dr. Cristian Scognamiglio



  • Intraoral situation of right lower quadrant.

  • Digital planning to establish a prosthetically-driven implant position.

  • Full-thickness flap was raised to allow access to the bone and evaluate the local anatomy. Alignment pin placed to check the 3D position of the osteotomy and preparation depth.

  • Implant in final position.

  • Radiographical control after insertion of dental implants.

  • Scanbody for digital impression.

  • Definitive screw-retained crown in position after 14 weeks.

  • Radiograph of final crown on Variobase® abutment screw-retained in final position.